physical-mechanical behaviour of recycled concretes elaborated with siliceous gravel
Abstract
The superficial texture of coarse aggregate modifies the interface zone and the adherence between aggregate and mortar. Recycled aggregates obtained from crushed waste concretes present a higher superficial ruggedness and porosity than natural aggregates, due to the mortar attached to the rock, which can affect the recycled aggregates properties and recycled concretes performance. This paper presents the results obtained on concretes elaborated with 50, 75 and 100% by replacement of natural coarse aggregate by recycled coarse aggregate obtained from crushed concrete elaborated with siliceous gravel. The results are compared with those obtained on conventional concrete (with natural coarse aggregate). It is observed that recycled concretes present strength levels similar to the conventional concrete, and their durable behaviors are satisfactory.
Full Text:
PDFReferences
Hansen, T.C., Recycled aggregates and recycled aggregate concrete. Second state of the art. Report developments 1945-1985, RILEM Technical Committee 37-DRC, Materials and Structures, Vol. 19, Nº 111, pp. 201-246.
Zega, C.J., Hormigones reciclados: evaluación mediante métodos vibracionales", Ciencia y Tecnología del Hormigón, LEMIT, Nº 10, 2003, pp. 65-71.
Metha, P.K., Monteiro, P.J.M., "Concreto: estructura, propiedades y materiales", Instituto Mexicano del Cemento y del Concreto, A. C., México, 1998.
Di Maio, A.A., Giaccio, G. y Zerbino, R., Hormigones con agregados reciclados, Ciencia y Tecnología del Hormigón, LEMIT, Nº 9, 2002, pp. 5-10.
Zega, C.J. y Di Maio, A.A., Influencia de las características de los agregados reciclados en la elaboración de hormigones, Memorias XV Reunión Técnica de la Asociación Argentina de Tecnología del Hormigón, AATH, Santa Fe, Octubre 2003. Ed. CD.
Zega, C.J., Fornasier, G., Ponce, M. y Di Maio, A.A., "Hormigones reciclados expuestos a ciclos rápidos de congelación y deshielo", Hormigón Nº 41, AATH, 2005, pp. 53-61.
Di Maio, A.A. y Traversa, L.P., Evaluation of recycled concrete by means of non destructive tests, Revista Materiales de Construcción, IETCC, Nºs 271-272, Vol. 53, Madrid, España, 2003, pp. 37-46. Revista Indexada en SCISearch, Research Alert y Materials Science Citation Index.
CIRSOC 201:2006. Reglamento Argentino de Estructuras de Hormigón, Instituto Nacional de Tecnología Industrial, Argentina. (en etapa de aprobación).
Norma IRAM 1554:1983. Hormigón de cemento portland. Método de determinación de la penetración de agua a presión en el hormigón endurecido.
Norma IRAM 1871:2004. Hormigón. Método de ensayo para determinar la capacidad y la velocidad de succión capilar de agua del hormigón endurecido.