Abstract


In order to improve operating reliability of cascade STATCOM (6KV, 8Mvar) with LCL filter, and on the foundation of an accurate diagnosis on device faults, the paper makes adjustments to soft and hard structures of cascade STATCOM. It is done to guarantee that the device can run in a steady and reliable way even when it has fault. The paper solves problems of fault tolerance control with the combined approaches of analytical redundancy and hardware redundancy (with tier-one redundancy), and also incorporates PWM modulation strategy and the phase-to-phase or in-phase capacitor voltage balance control strategy into frame, both of which need to be put into fault tolerance control. When some parts of the device fails, the main circuit is isolated from the fault model by blocking drive pulse and bypass mechanism. Finally, fault diagnosis and fault tolerance control combine with each other seamlessly. The simulation and the experimental results show together that fault tolerance control has a good effect on dynamic compensation and allows the device to respond promptly.


Full Text:

PDF

References


An Q.T., Sun L., Zhao K., Liu C., Yu L.N. (2010). Diagnosis method for inverter open-circuit fault Based on switching function model, Proceeding of the CSEE, 30(6), 1-6.

Chang W., Shi L.P., Wang S.j., Wang J. (2012). Application of space vector modulation in 6 kV cascade STATCOM, Power System Protection and Control, 40(12), 95-99.

Chen L.B., Shi L.P., Xia Z.L., Wang P.P. (2014). A reference current detection method based on synchronous reference frame transformation and DFT for SVG, Power System Protection and Control, 42(13), 21-27.

Huang J. (2012). The engineering practice of ±200 Mvar STATCOM in China south power grid, Southern Power System Technology, 6(9), 14-20.

Lian X.R. (2012).Control strategy research of modular multilevel STATCOM. Hangzhou: Chekiang University Library, 2012.

Lian X.R., Jiang D.Z. (2012). Fault-tolerant design and control of modular multilevel converter-based STATCOM, Power System Protection and Control, 40(16), 83-89.

Ni X.J., Zhao J.F., Cao W., Sun K., Huang H. (2010). Modulation reconfiguration of cascaded multilevel inverters under fault condition, Proceedings of the CSEE, 30(33), 16-22.

Xia Z.L., Shi L.P., Chen L.B., Yang X.D. (2013). Parameter design of cascade multilevel STATCOM in medium voltage based on LCL filter, Journal of China Coal Society, 38(8), 1503-1510.

Xia Z.L., Shi L.P., Yang X.D. (2014). Control Strategy of Cascade STATCOM Under Unbalanced Grid Condition, IETE Technical Review (Institution of Electronics and Telecommunication Engineers, India), 31(2), 177-185.

Xia Z.L., Shi L.P., Yang X.D., Li Q.Q. (2013). Current control strategy of cascade STATCOM based on LCL filter, Journal of China Coal Society, 38(12), 2272-2278.

Zhang M.S., Li S.S., Zha X.M., Sun J.J. Zhang H., Yin C.X. (2011). Robust performance criteria design for cascade D-STATCOM, Proceedings of the CSEE, 31(28), 71-79.

Zhang M.S., Zha X.M., Sun J.J., Zhang H., Zha Z.P. (2011). Passivity-based control of cascade D-STATCOM, Proceedings of the CSEE, 31(15), 33-39.


Refbacks

  • There are currently no refbacks.


Revista de la Facultad de Ingeniería,

ISSN: 2443-4477; ISSN-L:0798-4065

Edif. del Decanato de la Facultad de Ingeniería,

3º piso, Ciudad Universitaria,

Apartado 50.361, Caracas 1050-A,

Venezuela.

© Universidad Central de Venezuela